The reactive power control relays are designed to decrease the reactive powers not used by the loads in the system and drawn from the network due to the characteristics of the loads.
RGM-07E جهاز تنظيم وحدات تحسين معامل القدره (ريجليتور) 7 خطوة
It intervenes by activating a capacitor with suitable values if inductive power is drawn from the network. When it is energized after the connections of the device are completed, it controls the current transformer terminals by holding and releasing the stages respectively. After this test, it starts to intervene in the system. The memory input terminal is shorted out and the current transformer connection test is stored. It has the characteristics indicated below.
Single phase voltage and single phase current transformer.
It can compensate the inductive systems.
Easy-to-use
It shows the Cosφ value of the relevant phase to which it is connected on the display.
It functions through the method of holding and releasing respectively.
Company: Sehelly for trade and Industry
Product Documents
Documents
You must be logged in to post a review.
Related Products
-
LOW VOLTAGE PANLE
Availability: In stockOut of stock
Masar Engineering Industrials is specialized company in sheet metal manufacturing. One of our main products panels manufacturing and assembly of panels.
LOW VOLTAGE PANLE
Masar Engineering Industrials is specialized company in sheet metal manufacturing. One of our main products panels manufacturing and assembly of panels.
-
RGT-12 جهاز تنظيم وحدات تحسين معامل القدره (ريجليتور مكثفات) 12 خطوة مزود بشاشة لتحليل الشبكه +3شاشة لقياس الجهد / الامبير / التردد
Availability: In stockOut of stock
It intervenes by activating a capacitor with suitable values if inductive power is drawn from the network. It intervenes by activating a shunt reactor with suitable values if capacitive power is drawn from the network.
You are requested to enter the current transformer value at first when it is energized after the connections of the device are completed. After you enter and approve this value, the system controls the transformer terminals according to the power it draws. After this test is completed, it starts the stage test and tests all stages. After the stage test is completed, it starts to intervene according to the system requirement. It has the characteristics indicated below.
3-phase voltage and 3-phase current transformer
It can compensate the inductive and capacitive systems.
Single phase, two-phase and three-phase capacitor and shunt reactor may be connected.
It shows the active power, reactive power, Cosφ, THD, total active and total reactive energy values of each phase on LCD display.
It shows the 3-phase current, 3-phase voltage or 3-phase Cosφ values on the display.
It saves the total active and total reactive energy values.
The stage (capacitor and shunt reactor) value can be entered manually.
It shows the capacitor or reactor stage values individually for each phase.
The system intervention time can be adjusted.
Capacitor discharging time can be adjusted. Inductive/ Active and Capacitive / Active ratios (%) can be adjusted.
It saves the reactive power flow of the system.
Menu is password-protected.
It saves the number of stage use.
It provides equal number of stage use for the stages with the same values.
It shows the inductive/active and capacitive/active ratios reached.
It can set the inductive/active and capacitive/active ratios desired to be reached.
The stage layout time between two stages can be adjusted.
Off set stage can be created.
Time of intervention in the capacitive loads can be changed.
Time of intervention in the inductive loads can be changed.RGT-12 جهاز تنظيم وحدات تحسين معامل القدره (ريجليتور مكثفات) 12 خطوة مزود بشاشة لتحليل الشبكه +3شاشة لقياس الجهد / الامبير / التردد
It intervenes by activating a capacitor with suitable values if inductive power is drawn from the network. It intervenes by activating a shunt reactor with suitable values if capacitive power is drawn from the network.
You are requested to enter the current transformer value at first when it is energized after the connections of the device are completed. After you enter and approve this value, the system controls the transformer terminals according to the power it draws. After this test is completed, it starts the stage test and tests all stages. After the stage test is completed, it starts to intervene according to the system requirement. It has the characteristics indicated below.
3-phase voltage and 3-phase current transformer
It can compensate the inductive and capacitive systems.
Single phase, two-phase and three-phase capacitor and shunt reactor may be connected.
It shows the active power, reactive power, Cosφ, THD, total active and total reactive energy values of each phase on LCD display.
It shows the 3-phase current, 3-phase voltage or 3-phase Cosφ values on the display.
It saves the total active and total reactive energy values.
The stage (capacitor and shunt reactor) value can be entered manually.
It shows the capacitor or reactor stage values individually for each phase.
The system intervention time can be adjusted.
Capacitor discharging time can be adjusted. Inductive/ Active and Capacitive / Active ratios (%) can be adjusted.
It saves the reactive power flow of the system.
Menu is password-protected.
It saves the number of stage use.
It provides equal number of stage use for the stages with the same values.
It shows the inductive/active and capacitive/active ratios reached.
It can set the inductive/active and capacitive/active ratios desired to be reached.
The stage layout time between two stages can be adjusted.
Off set stage can be created.
Time of intervention in the capacitive loads can be changed.
Time of intervention in the inductive loads can be changed.
-
CONTROL PANEL
Availability: In stockOut of stock
Control Panel
Required for transformer
Substations 220/66/11KVCONTROL PANEL
Control Panel
Required for transformer
Substations 220/66/11KV
-
Low Voltage Switchgears – QuiXtra™ 630
Availability: In stockOut of stock
QuiXtra 630 has been developed as a range of system enclosures, GEs complete solution for low voltage distribution boards up to 630A for commercial and industrial environments.
Low Voltage Switchgears – QuiXtra™ 630
QuiXtra 630 has been developed as a range of system enclosures, GEs complete solution for low voltage distribution boards up to 630A for commercial and industrial environments.
-
-
Low Voltage Switchgears – SEK/SEV 32
Availability: In stockOut of stock
The standardized and type tested low voltage power distribution system from GE. The switchboard assemblies leave the manufacturing plant fully tested and ready for installation & commissioning.
Low Voltage Switchgears – SEK/SEV 32
The standardized and type tested low voltage power distribution system from GE. The switchboard assemblies leave the manufacturing plant fully tested and ready for installation & commissioning.
-
PROTECTION PANEL
Availability: In stockOut of stock
PROTECTION PANEL
Required for transformer
Substations 220/66/11KVPROTECTION PANEL
PROTECTION PANEL
Required for transformer
Substations 220/66/11KV
-
Power Factor Regulator, 8 Step -DPFC08B- 1402100
Availability: In stockOut of stock
Supply 220 – 230 – 380 – 400 – 440 VAC, With TTL THD, over&under (A,V)
and temperature Protection
Power Factor Regulator, 8 Step -DPFC08B- 1402100
Supply 220 – 230 – 380 – 400 – 440 VAC, With TTL THD, over&under (A,V)
and temperature Protection
-
Power Factor Regulator-DPFC12B – 1402101
Availability: In stockOut of stock
12 Step
بحمايه للتوافقيات
Supply 220 – 230 – 380 – 400 – 440 VAC,With TTL,THD, over&under (A,V) and temperature
ProtectionPower Factor Regulator-DPFC12B – 1402101
12 Step
بحمايه للتوافقيات
Supply 220 – 230 – 380 – 400 – 440 VAC,With TTL,THD, over&under (A,V) and temperature
Protection
RGM-07E جهاز تنظيم وحدات تحسين معامل القدره (ريجليتور) 7 خطوة
It intervenes by activating a capacitor with suitable values if inductive power is drawn from the network. When it is energized after the connections of the device are completed, it controls the current transformer terminals by holding and releasing the stages respectively. After this test, it starts to intervene in the system. The memory input terminal is shorted out and the current transformer connection test is stored. It has the characteristics indicated below.
Single phase voltage and single phase current transformer.
It can compensate the inductive systems.
Easy-to-use
It shows the Cosφ value of the relevant phase to which it is connected on the display.
It functions through the method of holding and releasing respectively.

Reviews
There are no reviews yet.