QuiXtra 4000 has been developed as a range of system enclosures, expansion of the line of QuiXtra 630
Low Voltage Switchgears – QuiXtra™ 4000
QuiXtra 4000 has been developed as a range of system enclosures, expansion of the line of QuiXtra 630
Company: ELECTRO GRORGE
Product Documents
Documents
You must be logged in to post a review.
Related Products
-
Battery Charger
Availability: In stockOut of stock
Battery Charger 110 and 220V DC up to 100A , 1ph and 3ph
Battery Charger
Battery Charger 110 and 220V DC up to 100A , 1ph and 3ph
-
RGT-12 جهاز تنظيم وحدات تحسين معامل القدره (ريجليتور مكثفات) 12 خطوة مزود بشاشة لتحليل الشبكه +3شاشة لقياس الجهد / الامبير / التردد
Availability: In stockOut of stock
12 Levels Three-Phase Reactive Power Control Relay
The reactive power control relays are designed to decrease the reactive powers (inductive and capacities) not used by the loads in the system and drawn from the network due to the characteristics of the loads
RGT-12 جهاز تنظيم وحدات تحسين معامل القدره (ريجليتور مكثفات) 12 خطوة مزود بشاشة لتحليل الشبكه +3شاشة لقياس الجهد / الامبير / التردد
12 Levels Three-Phase Reactive Power Control Relay
The reactive power control relays are designed to decrease the reactive powers (inductive and capacities) not used by the loads in the system and drawn from the network due to the characteristics of the loads
-
CONTROL PANEL
Availability: In stockOut of stock
Control Panel
Required for transformer
Substations 220/66/11KVCONTROL PANEL
Control Panel
Required for transformer
Substations 220/66/11KV
-
MOTOR CONTROL CENTER
Availability: In stockOut of stock
Motor Control Center
MCC380AC, up to 630A
Fixed and withdrawable type.MOTOR CONTROL CENTER
Motor Control Center
MCC380AC, up to 630A
Fixed and withdrawable type.
-
Power Factor Regulator, 8 Step -DPFC08B- 1402100
Availability: In stockOut of stock
Supply 220 – 230 – 380 – 400 – 440 VAC, With TTL THD, over&under (A,V)
and temperature Protection
Power Factor Regulator, 8 Step -DPFC08B- 1402100
Supply 220 – 230 – 380 – 400 – 440 VAC, With TTL THD, over&under (A,V)
and temperature Protection
-
RGT-12 جهاز تنظيم وحدات تحسين معامل القدره (ريجليتور مكثفات) 12 خطوة مزود بشاشة لتحليل الشبكه +3شاشة لقياس الجهد / الامبير / التردد
Availability: In stockOut of stock
It intervenes by activating a capacitor with suitable values if inductive power is drawn from the network. It intervenes by activating a shunt reactor with suitable values if capacitive power is drawn from the network.
You are requested to enter the current transformer value at first when it is energized after the connections of the device are completed. After you enter and approve this value, the system controls the transformer terminals according to the power it draws. After this test is completed, it starts the stage test and tests all stages. After the stage test is completed, it starts to intervene according to the system requirement. It has the characteristics indicated below.
3-phase voltage and 3-phase current transformer
It can compensate the inductive and capacitive systems.
Single phase, two-phase and three-phase capacitor and shunt reactor may be connected.
It shows the active power, reactive power, Cosφ, THD, total active and total reactive energy values of each phase on LCD display.
It shows the 3-phase current, 3-phase voltage or 3-phase Cosφ values on the display.
It saves the total active and total reactive energy values.
The stage (capacitor and shunt reactor) value can be entered manually.
It shows the capacitor or reactor stage values individually for each phase.
The system intervention time can be adjusted.
Capacitor discharging time can be adjusted. Inductive/ Active and Capacitive / Active ratios (%) can be adjusted.
It saves the reactive power flow of the system.
Menu is password-protected.
It saves the number of stage use.
It provides equal number of stage use for the stages with the same values.
It shows the inductive/active and capacitive/active ratios reached.
It can set the inductive/active and capacitive/active ratios desired to be reached.
The stage layout time between two stages can be adjusted.
Off set stage can be created.
Time of intervention in the capacitive loads can be changed.
Time of intervention in the inductive loads can be changed.RGT-12 جهاز تنظيم وحدات تحسين معامل القدره (ريجليتور مكثفات) 12 خطوة مزود بشاشة لتحليل الشبكه +3شاشة لقياس الجهد / الامبير / التردد
It intervenes by activating a capacitor with suitable values if inductive power is drawn from the network. It intervenes by activating a shunt reactor with suitable values if capacitive power is drawn from the network.
You are requested to enter the current transformer value at first when it is energized after the connections of the device are completed. After you enter and approve this value, the system controls the transformer terminals according to the power it draws. After this test is completed, it starts the stage test and tests all stages. After the stage test is completed, it starts to intervene according to the system requirement. It has the characteristics indicated below.
3-phase voltage and 3-phase current transformer
It can compensate the inductive and capacitive systems.
Single phase, two-phase and three-phase capacitor and shunt reactor may be connected.
It shows the active power, reactive power, Cosφ, THD, total active and total reactive energy values of each phase on LCD display.
It shows the 3-phase current, 3-phase voltage or 3-phase Cosφ values on the display.
It saves the total active and total reactive energy values.
The stage (capacitor and shunt reactor) value can be entered manually.
It shows the capacitor or reactor stage values individually for each phase.
The system intervention time can be adjusted.
Capacitor discharging time can be adjusted. Inductive/ Active and Capacitive / Active ratios (%) can be adjusted.
It saves the reactive power flow of the system.
Menu is password-protected.
It saves the number of stage use.
It provides equal number of stage use for the stages with the same values.
It shows the inductive/active and capacitive/active ratios reached.
It can set the inductive/active and capacitive/active ratios desired to be reached.
The stage layout time between two stages can be adjusted.
Off set stage can be created.
Time of intervention in the capacitive loads can be changed.
Time of intervention in the inductive loads can be changed.
-
Low Voltage Switchgears – Modular 200
Availability: In stockOut of stock
Modular 200 represents a complete range of type A and B MCB distribution boards and modular DIN rail – devices that are the result of comprehensive market research with customers.
Low Voltage Switchgears – Modular 200
Modular 200 represents a complete range of type A and B MCB distribution boards and modular DIN rail – devices that are the result of comprehensive market research with customers.
-
MARSHALLING PANEL
Availability: In stockOut of stock
Marshalling Panel
Required for transformer
Substations 220/66/11KVMARSHALLING PANEL
Marshalling Panel
Required for transformer
Substations 220/66/11KV
-
PROTECTION PANEL
Availability: In stockOut of stock
PROTECTION PANEL
Required for transformer
Substations 220/66/11KVPROTECTION PANEL
PROTECTION PANEL
Required for transformer
Substations 220/66/11KV
Low Voltage Switchgears – QuiXtra™ 4000
QuiXtra 4000 has been developed as a range of system enclosures, expansion of the line of QuiXtra 630

Reviews
There are no reviews yet.